* Example sketch for the ADS1115_WE library
*
* This sketch shows how to use the ADS1115 in single shot mode.
*
* Further information can be found on:
* https://wolles-elektronikkiste.de/ads1115
*
***************************************************************************/
#include<ADS1115_WE.h>
#include<Wire.h>
#define I2C_ADDRESS 0x48
ADS1115_WE adc(I2C_ADDRESS);
// ADS1115_WE adc = ADS1115_WE(); // Alternative: uses default address 0x48
void setup() {
Wire.begin();
Serial.begin(9600);
if(!adc.init()){
Serial.println("ADS1115 not connected!");
}
/* Set the voltage range of the ADC to adjust the gain
* Please note that you must not apply more than VDD + 0.3V to the input pins!
*
* ADS1115_RANGE_6144 -> +/- 6144 mV
* ADS1115_RANGE_4096 -> +/- 4096 mV
* ADS1115_RANGE_2048 -> +/- 2048 mV (default)
* ADS1115_RANGE_1024 -> +/- 1024 mV
* ADS1115_RANGE_0512 -> +/- 512 mV
* ADS1115_RANGE_0256 -> +/- 256 mV
*/
adc.setVoltageRange_mV(ADS1115_RANGE_6144); //comment line/change parameter to change range
/* Set the inputs to be compared
*
* ADS1115_COMP_0_1 -> compares 0 with 1 (default)
* ADS1115_COMP_0_3 -> compares 0 with 3
* ADS1115_COMP_1_3 -> compares 1 with 3
* ADS1115_COMP_2_3 -> compares 2 with 3
* ADS1115_COMP_0_GND -> compares 0 with GND
* ADS1115_COMP_1_GND -> compares 1 with GND
* ADS1115_COMP_2_GND -> compares 2 with GND
* ADS1115_COMP_3_GND -> compares 3 with GND
*/
//adc.setCompareChannels(ADS1115_COMP_0_GND); //uncomment if you want to change the default
/* Set number of conversions after which the alert pin will be active
* - or you can disable the alert
*
* ADS1115_ASSERT_AFTER_1 -> after 1 conversion
* ADS1115_ASSERT_AFTER_2 -> after 2 conversions
* ADS1115_ASSERT_AFTER_4 -> after 4 conversions
* ADS1115_DISABLE_ALERT -> disable comparator / alert pin (default)
*/
//adc.setAlertPinMode(ADS1115_ASSERT_AFTER_1); //uncomment if you want to change the default
/* Set the conversion rate in SPS (samples per second)
* Options should be self-explaining:
*
* ADS1115_8_SPS
* ADS1115_16_SPS
* ADS1115_32_SPS
* ADS1115_64_SPS
* ADS1115_128_SPS (default)
* ADS1115_250_SPS
* ADS1115_475_SPS
* ADS1115_860_SPS
*/
//adc.setConvRate(ADS1115_128_SPS); //uncomment if you want to change the default
/* Set continous or single shot mode:
*
* ADS1115_CONTINOUS -> continous mode
* ADS1115_SINGLE -> single shot mode (default)
*/
//adc.setMeasureMode(ADS1115_CONTINOUS); //uncomment if you want to change the default
/* Choose maximum limit or maxium and minimum alert limit (window)in Volt - alert pin will
* be active when measured values are beyond the maximum limit or outside the window
* Upper limit first: setAlertLimit_V(MODE, maximum, minimum)
* In max limit mode the minimum value is the limit where the alert pin will be deactivated (if
* not latched)
*
* ADS1115_MAX_LIMIT
* ADS1115_WINDOW
*
*/
//adc.setAlertModeAndLimit_V(ADS1115_MAX_LIMIT, 3.0, 1.5); //uncomment if you want to change the default
/* Enable or disable latch. If latch is enabled the alarm pin will be active until the
* conversion register is read (getResult functions). If disabled the alarm pin will be
* deactivated with next value within limits.
*
* ADS1115_LATCH_DISABLED (default)
* ADS1115_LATCH_ENABLED
*/
//adc.setAlertLatch(ADS1115_LATCH_ENABLED); //uncomment if you want to change the default
/* Sets the alert pin polarity if active:
*
* /* Enable or disable latch. If latch is enabled the alarm pin will be active until the
* conversion register is read (getResult functions). If disabled the alarm pin will be
* deactivated with next value within limits.
*
* ADS1115_ACT_LOW -> active low (default)
* ADS1115_ACT_HIGH -> active high
*/
//adc.setAlertPol(ADS1115_ACT_LOW); //uncomment if you want to change the default
/* With this function the alert pin will be active, when a conversion is ready.
* In order to deactivate, use the setAlertLimit_V function
*/
//adc.setAlertPinToConversionReady(); //uncomment if you want to change the default
Serial.println("ADS1115 Example Sketch - Single Shot Mode");
Serial.println();
}
void loop() {
float voltage = 0.0;
adc.setCompareChannels(ADS1115_COMP_0_GND);
adc.startSingleMeasurement();
while(adc.isBusy()){}
voltage = adc.getResult_V(); // alternative: getResult_mV for Millivolt
Serial.print("Channel 0 vs GND [V]: ");
Serial.println(voltage);
adc.setCompareChannels(ADS1115_COMP_1_GND);
adc.startSingleMeasurement();
while(adc.isBusy()){}
voltage = adc.getResult_V(); // alternative: getResult_mV for Millivolt
Serial.print("Channel 1 vs GND [V]: ");
Serial.println(voltage);
adc.setCompareChannels(ADS1115_COMP_2_GND);
adc.startSingleMeasurement();
while(adc.isBusy()){}
voltage = adc.getResult_V(); // alternative: getResult_mV for Millivolt
Serial.print("Channel 2 vs GND [V]: ");
Serial.println(voltage);
adc.setCompareChannels(ADS1115_COMP_3_GND);
adc.startSingleMeasurement();
while(adc.isBusy()){}
voltage = adc.getResult_V(); // alternative: getResult_mV for Millivolt
Serial.print("Channel 3 vs GND [V]: ");
Serial.println(voltage);
Serial.println("-------------------------------");
delay(2000);
}
|