summaryrefslogtreecommitdiffstats
path: root/_ont/ont-genexis-ft-g2110c.md
diff options
context:
space:
mode:
Diffstat (limited to '_ont/ont-genexis-ft-g2110c.md')
-rw-r--r--_ont/ont-genexis-ft-g2110c.md21
1 files changed, 10 insertions, 11 deletions
diff --git a/_ont/ont-genexis-ft-g2110c.md b/_ont/ont-genexis-ft-g2110c.md
index 8a95a31..4aeee5a 100644
--- a/_ont/ont-genexis-ft-g2110c.md
+++ b/_ont/ont-genexis-ft-g2110c.md
@@ -43,7 +43,7 @@ The ONT has a TTL 3.3v UART console (configured as 115200 8-N-1) that can be acc
{% include image.html file="ft-g2110c-internal.jpg" alt="FiberTwist G2110C-2.5G Internal" caption="FiberTwist G2110C-2.5G Internal" %}
-{% include alert.html content="Some USB TTL adapters label TX and RX pins the other way around: try to swap them if the connection doesn't work." alert="Note" icon="svg-warning" color="yellow" %}
+{% include alert.html content="Some USB TTL adapters label TX and RX pins the other way around: try swapping them if the connection doesn't work." alert="Note" icon="svg-warning" color="yellow" %}
## List of software versions
- C-5.6.1-R
@@ -76,7 +76,7 @@ This ONT supports dual boot.
# GPON/OMCI settings
-{% include alert.html content="Some variables are write-protected, you need to unlock them before proceed" alert="Info" icon="svg-info" color="blue" %}
+{% include alert.html content="Some variables are write-protected, you need to unlock them before proceeding" alert="Info" icon="svg-info" color="blue" %}
Use the following command to unlock write-protected variables:
@@ -93,7 +93,7 @@ Use the following command to unlock write-protected variables:
```
Reboot the ONT to apply any changes
-You can check if the serial number was correclty changed using the following command:
+You can check if the serial number was correctly changed using the following command:
```sh
# diag gpon get serialnumber
@@ -109,8 +109,8 @@ ZTEGaaa01234
GPON_PLOAM_PASSWD=AAAAAAAAAA
# /etc/scripts/flash set GPON_PLOAM_PASSWD AAAAAAAAAA
```
-Looks like Genexis has also included an U-Boot variable to store the PLOAM. On currently known firmwares (5.6.1 and 5.7.0) it is not read by the `omci_app` daemon.
-If you want to be future proof, put your PLOAM also on U-Boot env using the following command in the OS shell:
+It seems Genexis has also included a U-Boot variable to store the PLOAM. On currently known firmwares (5.6.1 and 5.7.0) it is not read by the `omci_app` daemon.
+For future-proofing reasons, set your PLOAM also on the before-mentioned U-Boot env using the following command in the OS shell:
```sh
# nv setenv ploampwd 1234567890
@@ -119,10 +119,9 @@ ploampwd=1234567890
## Setting OMCI software version (ME 7)
The stock firware does not allow changing of the primary and standby software version.
-Since the ONT uses the Luna SDK, the `/etc/scripts/flash` shell script can be easily modified by creating a custom firmware with
-the same set of patches suggested e.g. for the [Technicolor AFM0002](/ont-technicolor-afm0002) ONT.
+As the ONT uses the Luna SDK, the `/etc/scripts/flash` shell script can be easily modified by creating a custom firmware with the same set of patches suggested e.g. for the [Technicolor AFM0002](/ont-technicolor-afm0002) ONT.
-You can then check if the software version was correctly changed with this command (take a look at the `Version` field):
+You can then check if the software version was changed correctly with this command (take a look at the `Version` field):
```sh
# omcicli mib get 7
@@ -154,14 +153,14 @@ ImageHash: 0x00000000000000000000000000000000
```sh
# nv setenv HV G2110CE2V1D0
```
-Reboot ONT to apply the change
+Reboot the ONT to apply the change
## Setting OMCI equipment ID (ME 257)
```sh
# nv setenv ProdName FT-G2110C-2.5G
```
-Reboot ONT to apply the change
+Reboot the ONT to apply the change
# Advanced settings
@@ -173,7 +172,7 @@ LAN_IP_ADDR=192.168.1.1
```
# Known Bugs
-- Web UI can be enabled by modding the firmware, but without an attached fiber the daemon will crash
+- The web UI can be enabled by modding the firmware, but the daemon will crash if no optical signal is received
# Miscellaneous Links
- [FiberTwist G2110C-2.5G](https://genexis.eu/content/uploads/2020/07/FiberTwist-G2110C-2.5G-Installation-Guide-v1.0-EN.pdf)